Toyota Camry (XV70): Front Window Fogging

DESCRIPTION

If the windshield frequently fogs up even though the air conditioning system is operating, the following suspected areas may be the cause.

Symptom

Factor

Windshield frequently fogs up

  • Compressor assembly with pulley (compressor solenoid) malfunction
  • Refrigerant volume (low)
  • Cooler expansion valve (opened excessively)
  • No. 1 air conditioning radiator damper servo sub-assembly (mode) malfunction
  • Mechanical locking of damper and damper link

PROCEDURE

1.

PERFORM PERFORM REFRIGERANT SHORTAGE

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn the Techstream on.

(d) Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.

Body Electrical > Air Conditioner > Utility

Tester Display

Refrigerant Gas Volume Check

(e) Check that the following conditions are met and perform the refrigerant shortage check according to the display on the Techstream.

Measurement Condition:

Item

Condition

A/C switch

On

Ambient temperature*

0 to 49°C (32 to 120°F)

Blower speed

HI

*: If the ambient temperature is not within the range shown, do not perform this check.

Result

Amount of Refrigerant

Refrigerant correct

Correct

Refrigerant shortage

Insufficient

OK:

"Refrigerant correct" is displayed on Techstream.

NG

CHARGE SYSTEM WITH REFRIGERANT

OK

2.

CHECK OPERATION

(a) Press the front defroster switch on the air conditioning control assembly and check that the air outlet mode changes to DEF mode.

OK:

The air outlet mode changes to DEF mode.

OK

INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET

NG

GO TO DTC B1443

    READ NEXT:

     Blower Motor does not Operate

    DESCRIPTION If air does not flow from the front registers after the blower switch on the air conditioning control assembly is operated, the following suspected areas may be the cause. Symptom F

     Weak Blower Output

    DESCRIPTION If the airflow from the front registers is weak regardless of the blower speed setting displayed on the air conditioning control assembly, the following suspected areas may be the cause.

     Pressure Sensor Circuit

    DESCRIPTION Based on signals from the air conditioner pressure sensor, the air conditioning amplifier assembly controls the compressor solenoid of the compressor assembly with pulley and changes the a

    SEE MORE:

     Electric Throttle Malfunction (B15E5)

    DESCRIPTION DTC No. Detection Item DTC Detection Condition Trouble Area B15E5 Electric Throttle Malfunction Electric throttle sensor malfunction CAN communication system SFI system Radio and display receiver assembly CAUTION / NOTICE / H

     Terminals Of Ecu

    TERMINALS OF ECU CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY *A w/o Seat Heater *B w/ Seat Heater HINT: Check from the rear of the connector while it is connected to the air conditioning amplifier assembly. Make sure to wait at least 2 minutes after turning the ignition switch

    © 2023-2026 Copyright www.tocamry.com