DESCRIPTION
If the airflow from the front registers is weak regardless of the blower speed setting displayed on the air conditioning control assembly, the following suspected areas may be the cause.
|
Symptom | Factor |
|---|---|
|
|
PROCEDURE
| 1. |
CHECK AIR CONDITIONING SYSTEM |
(a) Operate the blower switch with the following conditions met and check that the airflow volume changes.
|
Blower Speed | Condition |
|---|---|
|
LO > HI |
|
OK:
Airflow volume increases.
| NG | | GO TO OTHER DIAGNOSIS PROCEDURE (Blower Motor Circuit) |
|
| 2. |
CHECK CLEAN AIR FILTER |
(a) Visually check the clean air filter.
Click here
OK:
The clean air filter is not dirty or clogged.
| NG | | REPLACE CLEAN AIR FILTER |
|
| 3. |
CHECK NO. 1 COOLER THERMISTOR |
(a) Check the installation condition of the No. 1 cooler thermistor.
OK:
The No. 1 cooler thermistor is installed correctly.
| NG | | INSTALL NO. 1 COOLER THERMISTOR CORRECTLY |
|
| 4. |
CHECK ASPIRATOR |
(a) Check the installation condition of the aspirator.
OK:
The aspirator is installed correctly.
| OK | | REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY (HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY WAS CLOGGING)
|
| NG | | INSTALL ASPIRATOR CORRECTLY
|
Position Initialization Incomplete (B2343)
Customization