DESCRIPTION

Refer to DTC C050C12

Click here

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

C050C24

Left Rear Wheel Speed Sensor Signal Stuck High

The speed sensor signal is not within the specified range for 5 seconds or more.

Rear speed sensor LH (rear axle hub and bearing assembly LH)

CAUTION / NOTICE / HINT

NOTICE:

After replacing or removing and installing a speed sensor, perform Dealer Mode (Signal Check) inspection to confirm that the speed sensors are operating correctly.

Click here

PROCEDURE

1.

REPLACE REAR AXLE HUB AND BEARING ASSEMBLY LH

(a) Replace the rear axle hub and bearing assembly LH.

Click here

NEXT

END

    READ NEXT:

     Left Rear Wheel Speed Sensor Internal Electronic Failure (C050C49)

    DESCRIPTION When the system is starting up and the skid control ECU (brake actuator assembly) detects a speed sensor circuit malfunction via the speed sensor circuit self-diagnosis function, this DTC

     Right Rear Wheel Speed Sensor Circuit Short to Battery (C051212)

    DESCRIPTION Each speed sensor detects wheel speed and sends signals to the skid control ECU (brake actuator assembly). These signals are used by the ABS control. The speed sensor detects the magneti

     Right Rear Wheel Speed Sensor Circuit Short to Ground or Open (C051214)

    DESCRIPTION Refer to DTC C051212 Click here DTC No. Detection Item DTC Detection Condition Trouble Area C051214 Right Rear Wheel Speed Sensor Circuit Short to Ground or Op

    SEE MORE:

     Installation

    INSTALLATION PROCEDURE 1. INSTALL REAR UPPER CONTROL ARM ASSEMBLY LH (for 2WD) (a) Temporarily install the rear upper control arm assembly LH to the rear suspension member sub-assembly with the bolt and nut. NOTICE: Because the nut has its own stopper, do not turn the nut. Tighten the

     Evaporator Temperature Circuit or Evaporator Fin Thermistor (B1413)

    DESCRIPTION The No. 1 cooler thermistor is installed to the evaporator in the air conditioner unit to detect the temperature of the cooled air that has passed through the evaporator, which is used to control the air conditioning system. It sends signals to the air conditioning amplifier assembly. Th

    © 2023-2026 Copyright www.tocamry.com