DESCRIPTION
This DTC is stored if the amount of refrigerant in the in the air conditioning system exceeds a threshold. The air conditioning amplifier assembly judges whether the amount of refrigerant is appropriate based on the detected refrigerant pressure and the compressor assembly with pulley (compressor solenoid) operation current. If the amount of refrigerant in the system is determined to have exceeded a threshold, operation of the compressor assembly with pulley (compressor solenoid) will be stopped, and will remain stopped even if the ignition switch is turned off and then the engine is restarted.
|
DTC No. | Detection Item |
DTC Detection Condition | Trouble Area |
Memory |
|---|---|---|---|---|
| B14BD |
Refrigerant Overabundance Filling Malfunction |
All of the following conditions are met 2 times or more in the same trip:
|
| Memorized (60 sec. or more)* |
|
*a | Electric Current (mA) |
*b | Refrigerant Pressure kPa (kgf/cm2, psi) |
PROCEDURE
| 1. |
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM |
(a) Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.
Click here
|
| 2. |
CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT |
Click here
| NEXT | | END |
Removal