DESCRIPTION
If warm air blows from the registers regardless of the temperature setting of the air conditioning system, the following suspected areas may be the cause.
|
Symptom | Factor |
|---|---|
|
No cool air comes out (Blower control is normal) |
|
PROCEDURE
|
1. | CHECK SWITCH INDICATOR |
(a) Operate each switch on the air conditioning control panel and check that the switch indicators operate normally.
OK:
All switch indicators operate normally.
| NG | | GO TO OTHER DIAGNOSIS PROCEDURE (Operation not Accepted Even If Air Conditioning Switch is Operated) |
|
| 2. |
PERFORM ACTIVE TEST USING TECHSTREAM |
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Active Test.
(e) Perform the Active Test according to the display on the Techstream.
Body Electrical > Air Conditioner > Active Test|
Tester Display | Measurement Item |
Control Range | Diagnostic Note |
|---|---|---|---|
|
Air Mix Servo Targ Pulse(D) |
No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix*1 or air mix*2) pulse |
Min.: 128 Max.: 383 |
Operates between 165 to 257 pulses |
|
Air Mix Servo Targ Pulse(P) |
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse*1 |
Min.: 128 Max.: 383 |
Operates between 255 to 347 pulses |
|
Air Outlet Servo Pulse (D) |
No. 1 air conditioning radiator damper servo sub-assembly (mode) pulse |
Min.: 128 Max.: 383 |
Operates between 241 to 348 pulses |
|
Air Inlet Damper Targ Pulse |
No. 1 blower damper servo sub-assembly pulse |
Min.: 128 Max.: 383 |
Operates between 220 to 256 pulses |
|
A/O Servo Pulse(Rr D) | No. 2 air conditioning radiator damper servo sub-assembly pulse*3 |
Min.: 128 Max.: 383 |
Operates between 158 to 260 pulses |
|
Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
|
Tester Display |
|---|
| Air Mix Servo Targ Pulse(P) |
|
Tester Display |
|---|
| Air Outlet Servo Pulse (D) |
|
Tester Display |
|---|
| Air Inlet Damper Targ Pulse |
|
Tester Display |
|---|
| A/O Servo Pulse(Rr D) |
OK:
Each damper servo motor operates.
| OK | | INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET |
| NG | | GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR |
Dcm Operation History
Removal