DESCRIPTION
If the cooling effect of the air conditioning system is weak, the following suspected areas may be the cause.
|
Symptom | Factor |
|---|---|
|
|
PROCEDURE
| 1. |
PERFORM REFRIGERANT SHORTAGE CHECK |
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
Body Electrical > Air Conditioner > Utility|
Tester Display |
|---|
| Refrigerant Gas Volume Check |
(e) Check that the following conditions are met and perform the refrigerant shortage check according to the display on the Techstream.
Measurement Condition:|
Item | Condition |
|---|---|
|
A/C switch | On |
|
Ambient temperature* |
0 to 49°C (32 to 120°F) |
|
Blower speed | HI |
*: If the ambient temperature is not within the range shown, do not perform this check.
|
Result | Amount of Refrigerant |
|---|---|
|
Refrigerant correct | Correct |
|
Refrigerant shortage |
Insufficient |
OK:
"Refrigerant correct" is displayed on Techstream.
| NG | | REPAIR REFRIGERANT LEAK |
|
| 2. |
PERFORM ACTIVE TEST USING TECHSTREAM |
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Active Test.
(e) Perform the Active Test according to the display on the Techstream.
Body Electrical > Air Conditioner > Active Test|
Tester Display | Measurement Item |
Control Range | Diagnostic Note |
|---|---|---|---|
|
Blower Motor | Blower motor with fan sub-assembly |
Min.: 0 Max.: 31 |
- |
| Air Mix Servo Targ Pulse(D) |
No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse |
Min.: 128 Max.: 383 |
Operates between 165 to 257 pulses |
|
Air Outlet Servo Pulse (D) |
No. 1 air conditioning radiator damper servo sub-assembly (mode) pulse |
Min.: 128 Max.: 383 |
Operates between 241 to 348 pulses |
|
Air Inlet Damper Targ Pulse |
No. 1 blower damper servo sub-assembly pulse |
Min.: 128 Max.: 383 |
Operates between 220 to 256 pulses |
|
Tester Display |
|---|
| Blower Motor |
|
Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
|
Tester Display |
|---|
| Air Outlet Servo Pulse (D) |
|
Tester Display |
|---|
| Air Inlet Damper Targ Pulse |
OK:
The blower motor with fan sub-assembly and each damper servo motor operates.
| OK | | INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET |
| NG | | GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR |
Installation
Cooling System