Toyota Camry owners & service manuals

Toyota Camry (XV70): Front Window Fogging

DESCRIPTION

If the windshield frequently fogs up even though the air conditioning system is operating, the following suspected areas may be the cause.

Symptom

Factor

Windshield frequently fogs up

  • Compressor assembly with pulley (compressor solenoid) malfunction*1
  • Cooler compressor assembly (compressor solenoid) malfunction*2
  • Refrigerant volume (low)
  • Cooler expansion valve (opened excessively)
  • No. 1 air conditioning radiator damper servo sub-assembly (mode) malfunction
  • Mechanical locking of damper and damper link
  • *1: for A25A-FKS
  • *2: for 2GR-FKS

PROCEDURE

1.

PERFORM REFRIGERANT SHORTAGE CHECK

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn the Techstream on.

(d) Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.

Body Electrical > Air Conditioner > Utility

Tester Display

Refrigerant Gas Volume Check

(e) Check that the following conditions are met and perform the refrigerant shortage check according to the display on the Techstream.

Measurement Condition:

Item

Condition

A/C switch

On

Ambient temperature*

0 to 49°C (32 to 120°F)

Blower speed

HI

*: If the ambient temperature is not within the range shown, do not perform this check.

Result

Amount of Refrigerant

Refrigerant correct

Correct

Refrigerant shortage

Insufficient

OK:

"Refrigerant correct" is displayed on Techstream.

NG

CHARGE SYSTEM WITH REFRIGERANT

OK

2.

CHECK OPERATION

(a) Press the front defroster switch on the air conditioning control assembly and check that the air outlet mode changes to DEF mode.

OK:

The air outlet mode changes to DEF mode.

OK

INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET

NG

GO TO DTC B1443

    READ NEXT:

     Blower Motor does not Operate

    DESCRIPTION If air does not flow from the front registers after the blower switch on the air conditioning control assembly is operated, the following suspected areas may be the cause. Symptom F

     Weak Blower Output

    DESCRIPTION If the airflow from the front registers is weak regardless of the blower speed setting displayed on the air conditioning control assembly, the following suspected areas may be the cause.

     Pressure Sensor Circuit

    DESCRIPTION Based on signals from the air conditioner pressure sensor, the air conditioning amplifier assembly controls the compressor assembly with pulley (compressor solenoid)*1 or cooler compressor

    SEE MORE:

     Radio Broadcast cannot be Received or Poor Reception

    CAUTION / NOTICE / HINT NOTICE: Depending on the parts that are replaced during vehicle inspection or maintenance, performing initialization, registration or calibration may be needed. Refer to Precaution for Audio and Visual System. Click here When replacing the radio and display

     Differential Oil

    ComponentsCOMPONENTS ILLUSTRATION *1 REAR DIFFERENTIAL FILLER PLUG *2 REAR DIFFERENTIAL DRAIN PLUG *3 GASKET - - N*m (kgf*cm, ft.*lbf): Specified torque ● Non-reusable part ReplacementREPLACEMENT PROCEDURE 1. DRAIN DIFFERENTIAL

    © 2023-2026 Copyright www.tocamry.com