Toyota Camry (XV70): Installation
INSTALLATION
PROCEDURE
1. INSTALL MASS AIR FLOW METER SUB-ASSEMBLY
HINT:
Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.
Click here
(a) Install the mass air flow meter sub-assembly to the air cleaner cap sub-assembly with the 2 screws.
NOTICE:
- If the mass air flow meter sub-assembly has been struck or dropped, replace it.
- If reusing the mass air flow meter sub-assembly, be sure to inspect the O-ring.
- Make sure that the O-ring is not cracked or moved out of place when installing the mass air flow meter sub-assembly.
(b) Connect the mass air flow meter sub-assembly connector.
2. PERFORM INITIALIZATION
(a) Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.
Click here
READ NEXT:
On-vehicle InspectionON-VEHICLE INSPECTION PROCEDURE
1. INSPECT NO. 1 ELECTRONIC FUEL INJECTION MAIN RELAY (EFI-MAIN NO. 1)
(a) Measure the resistance according to the value(s) in the table be
PRECAUTION INITIALIZATION
NOTICE:
Before replacing the ECM, refer to Registration.
Click here
Perform Registration (VIN registration) after replacing the ECM.
Click here
Perform L
SEE MORE:
REMOVAL CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during rear drive shaft assembly removal/installation are shown below. Necessary Procedures After Parts Remo
COMPONENTS ILLUSTRATION
*1 ENGINE WIRE
*2 NO. 1 VACUUM HOSE CONNECTOR
*3 VACUUM PUMP ASSEMBLY
*4 NO. 1 VACUUM PUMP O-RING
Tightening torque for "Major areas involving basic vehicle performance such as moving/turning/stopping": N*m (kgf*cm, ft.*lbf