DESCRIPTION
If none of the switch indicators on the air conditioning control assembly illuminate, the following suspected areas may be the cause.
|
Symptom | Factor |
|---|---|
|
None of the switch indicators on the air conditioning control assembly illuminate |
|
PROCEDURE
| 1. |
CHECK AIR CONDITIONING CONTROL ASSEMBLY |
(a) Check that the switch indicators on the air conditioning control assembly illuminate immediately after the engine is started.
OK:
All switch indicators illuminate.
| NG | | REPLACE AIR CONDITIONING CONTROL ASSEMBLY |
|
| 2. |
READ VALUE USING TECHSTREAM |
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List|
Tester Display | Measurement Item |
Range | Normal Condition |
Diagnostic Note |
|---|---|---|---|---|
|
Ambient Temp Sensor | Thermistor assembly |
Min.: -23.30°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed |
- |
|
Tester Display |
|---|
| Ambient Temp Sensor |
OK:
The value displayed is 0°C (32°F) or higher.
| OK | | INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET |
| NG | | GO TO OTHER DIAGNOSIS PROCEDURE (Ambient Temperature Display System) |
How To Proceed With Troubleshooting
Indicator (Red) Circuit Short to Ground (B157011,B157013)