DESCRIPTION
This DTC is stored if the amount of refrigerant in the in the air conditioning system exceeds a threshold. The air conditioning amplifier assembly judges whether the amount of refrigerant is appropriate based on the detected refrigerant pressure and the compressor assembly with pulley (compressor solenoid)*1 or cooler compressor assembly (compressor solenoid)*2 operation current. If the amount of refrigerant in the system is determined to have exceeded a threshold, operation of the compressor assembly with pulley (compressor solenoid)*1 or cooler compressor assembly (compressor solenoid)*2 will be stopped, and will remain stopped even if the ignition switch is turned off and then the engine is restarted.
|
DTC No. | Detection Item |
DTC Detection Condition | Trouble Area |
Memory |
|---|---|---|---|---|
| B14BD |
Refrigerant Overabundance Filling Malfunction |
All of the following conditions are met 2 times or more in the same trip:
|
| Memorized (60 sec. or more)*3 |
|
*a | Electric Current (mA) |
*b | Refrigerant Pressure kPa (kgf/cm2, psi) |
PROCEDURE
| 1. |
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM |
(a) Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.
Click here
|
| 2. |
CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT |
Click here
| NEXT | | END |
Removal
Freeze Frame Data