Toyota Camry owners & service manuals

Toyota Camry (XV70): 2gr-fks (engine Mechanical)

READ NEXT:

 Camshaft

 Components

COMPONENTS ILLUSTRATION *1 VENTILATION HOSE *2 PURGE VALVE (PURGE VSV) *3 NO. 1 FUEL VAPOR FEED HOSE *4 NO. 2 SURGE TANK STAY *5 INTAKE AIR SURGE TANK A

 Removal

REMOVAL CAUTION / NOTICE / HINT The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during c

SEE MORE:

 Charging Failure

PROCEDURE 1. CHECK GENERATOR PULLEY WITH CLUTCH (ON-VEHICLE INSPECTION) (a) Start the engine and visually check that the generator rotor assembly (fan) in the generator assembly is operating. OK: The generator rotor assembly (fan) is operating. NG REPLACE GENERATOR PULLE

 Disassembly

DISASSEMBLY PROCEDURE 1. REMOVE STEERING RACK BOOT CLIP (for LH Side) (a) Using pliers, remove the steering rack boot clip. 2. REMOVE STEERING RACK BOOT CLIP (for RH Side) HINT: Perform the same procedure as for the LH side. 3. REMOVE NO. 2 STEERING RACK BOOT CLAMP (for LH Side) (a) Usi