Toyota Camry (XV70): 2gr-fks (engine Mechanical)
READ NEXT:
COMPONENTS ILLUSTRATION
*1 VENTILATION HOSE
*2 PURGE VALVE (PURGE VSV)
*3 NO. 1 FUEL VAPOR FEED HOSE
*4 NO. 2 SURGE TANK STAY
*5 INTAKE AIR SURGE TANK A
REMOVAL CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during c
SEE MORE:
INSPECTION PROCEDURE 1. INSPECT FLOW SHUTTING VALVE (NO. 1 WATER BY-PASS HOSE)
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection Condition
Specified Condition
1 - 2 20°C (68°F)
22 to 28 Ω
INSTALLATION PROCEDURE 1. INSTALL V-RIBBED BELT
HINT: When reusing the V-ribbed belt, check the ribs and back of the V-ribbed belt for wear and cracks. If wear or a crack that reaches the core (at more than 1 point) is found, replace the V-ribbed belt.
(a) Set the V-ribbed belt onto each pul