Toyota Camry owners & service manuals

Toyota Camry (XV70): Inspection

INSPECTION

PROCEDURE

1. INSPECT FLOW SHUTTING VALVE (NO. 1 WATER BY-PASS HOSE)

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

1 - 2

20°C (68°F)

22 to 28 Ω

If the result is not as specified, replace the flow shutting valve (No. 1 water by-pass hose).

*a

Component without harness connected

(Flow Shutting Valve (No. 1 Water By-pass Hose))

    READ NEXT:

     Installation

    INSTALLATION PROCEDURE 1. INSTALL FLOW SHUTTING VALVE (NO. 1 WATER BY-PASS HOSE) (a) Install the flow shutting valve (No. 1 water by-pass hose) with the bolt. Torque: 19 N·m {194 kgf·cm, 14 ftÂ

     Flow Shutting Valve(for Heater)

     Components

    COMPONENTS ILLUSTRATION *1 FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY) *2 VACUUM HOSE *3 ENGINE WIRE HARNESS *4 OUTLET HEATER HOSE *5 INLET HEATER

    SEE MORE:

     Installation

    INSTALLATION PROCEDURE 1. INSTALL AIR FUEL RATIO SENSOR (for Bank 1) HINT: Perform "Inspection After Repair" after replacing the air fuel ratio sensor. Click here (a) Using SST, install the air fuel ratio sensor to the exhaust manifold assembly RH (TWC: Front Catalyst). SST: 09224

     Reassembly

    REASSEMBLY PROCEDURE 1. INSTALL OIL PUMP ROTOR SET (a) Coat the drive rotor and driven rotor with engine oil and place them into the timing chain cover assembly with the rotor marks facing up. Check that the rotors rotate smoothly. *a Rotor Mark 2. I